How low an outside temp before disabling a heat pump? - HVAC …
2022年12月14日 · The heat pump would shut off and the oil would heat the house to satisfy the thermostat. As the house cools down the heat pump would start 1st and the cycle would repeat. The problem with this is as the heat pump reaches temperatures where it won’t keep the house warm the register air will be cooler. Then it is just a matter of cost over comfort.
Minimum outside temperature for heat pump compressor - HVAC …
2024年11月22日 · The description on the invoice is "Heat Pump, Lennox Merit Series, 16 Seer, 4 Ton, 2 Stage, R-410A, 17H25, Minimum outside temperature for heat pump compressor Help
Heatpump compressor vs whole unit replacement - HVAC-Talk
2011年3月26日 · Putting a 13 SEER heat pump on a 10 SEER indoor unit, causes problems with refrigerant charge imbalance. Over charged in heating mode, under charged in cooling mode. Can shorten the new condensers compressor life.
Recommended Thermostat Cycle Rate Settings - HVAC-Talk
2011年1月20日 · I recently installed a Honeywell Prestige thermostat for my Bryant 4-ton electric heat pump. The heat pump has 1 compressor stage and 1 auxiliary heat stage (electric heat strips). The thermostat has settings for the cycle rate for each stage. The default settings are 3 cph for the compressor stage and 9 cph for the auxiliary heat stage.
What temp for Heatpump lockout? - HVAC-Talk
2009年12月5日 · Even at 17 degrees outside, the heat pump is typically 2.5 times as efficient as strip heat. I would not lock out the compressor at all. Also I don't recommend setback for a heat pump, especially below 40 degrees outside.
How to set the compressor cut-off temperature on a Carrier heat …
2022年1月20日 · I believe the heat pump has a single stage compressor. - Carrier heat pump 25HCC560A300 - Carrier Air handler: FV4CNB006 with 20KW heat strips - Nest learning thermostat (I know, not the forum's favorite) Air handler is installed in the attic with a relatively long run to the outside unit (50+ feet). I set the indoor heat to 68F day, 64F night.
Heat pump failure: Compressor or Reversing Valve? - HVAC-Talk
2008年1月19日 · My heat pump has failed. Compressor will start but then quit shortly later. Inside blower and condenser unit fan continue to run. Tech A says it's a bad reversing valve. No temp difference between discharge suction lines in or out of reversing valve. Believes valve solenoid is clicking, but valve isn't switching. Tech B says it's a bad compressor.
Compressor making loud noise on start up - HVAC-Talk
2013年7月5日 · We just had a hard start kit installed last week in our first floor 2012 Trane XR15 3.5 ton heat pump. My son kept complaining about the unit making a loud noise when the unit starts up (his bedroom is right by A/C units). I'm also able to hear it in the kitchen and outside, even standing a very long distance from the unit.
heat pump equal pressure problems - HVAC-Talk
2010年6月30日 · heat pump my bad with the run on sentence. its a lennox hpx15 3 ton system . reversing valve makes no noise what so ever was told by manufacture that i should see some pressure even if stuck in dead center. equalizes at 175 system running or not. as if compresser is not pumping, compresser never goes out on thermal
Advice Needed: Heat Pump Compressor Intermittently Shuts on …
2011年2月7日 · Situation: I have a 3-ton ground-source heat pump which I use for heating and cooling. The unit is about 2 years old. The unit is in my basement, when I run it continually the compressor will shut off every 3 hours or so for about 30 …